 DATA S H E E T
MIDIUM POWER TRAVELING WAVE TUBE FOR COMMUNICATIONS
LD7714
30 GHz, 40 W CW, Conduction Cooling, Mimimum Size
GENERAL DESCRIPTION
The NEC LD7714 is a PPM-focused traveling wave tube designed for use as final amplifier in the earth-tosatellite communications transmitter, LMDS (Local Multipoint distribution service) and other advanced communication systems. This is capable of delivering an output power of 40 W over the range of 27.5 to 30.0 GHz and provides a power gain of more than 40 dB at 40 W level. Furthermore, it is of rugged and reliable design offering long-life service.
FEATURES
TM Lightweight, Compact and Efficient The tube has a dual-depressed collectors and designed to operate at high efficiency across the power output range. It features state-of-the-art techniques to optimize size and efficiency. TM Low Distortion Distortion is a very important factor in multiplex digital signals transmission. NEC has developed techniques for the correction of non-linear distortion and phase generated in a TWT. As a result, the TWT has an optimum performance across a broad power range and is ideally suited for multi-carrier trancmission systems. TM Simple Cooling System The tube is conduction cooled, so that the cooling system is simplified. TM Rugged Construction The power gain is designed to be rugged, therefore it is suitable for transportable systems. TM Long Life and High Stability The tube employs an advanced impregnated cathode with a low operating temperature for long life. TM Micro-discharge Free The tube is carefully designed to be free from microdischarge in the electron gun for long term operation, therefore it is suitable for digital communication service.
For safe use of microwave tubes, refer to NEC document "Safety instructions to all personnel handling electron tubes" (ET0048EJVUM00)
The information in this document is subject to change without notice.
Document No. ET0454EJ1V0DS00 Date Published August 1999 M Printed in Japan
(c)
1999
LD7714
GENERAL CHARACTERISTICS
ELECTRICAL Frequency ...................................................... 27.5 to 30.0 GHz Output Power ................................................ 40 W Heater Voltage ................................................ 6.3 V Heater Current ................................................ 0.82 A Heater Surge Current .................................... 2.5 A Type of Cathode ............................................. Indirectly heated, Impregnated Cathode Warm-up Time ................................. 180 s MECHANICAL Dimensions ................................................... See Outline Weight ......................................................... 700 g approx. Focusing ...................................................... Periodic Permanent Magnet Mounting Position .......................................... Any Electrical Connections .................................... Flying Leads RF Connections Input ......................................................... Mates with UG-599/U Flange or K connector Female Output ...................................................... Mates with UG-599/U Flange Cooling ......................................................... Conduction
ABSOLUTE RATINGS (Note 1, 2 and 3 )
ELECTRICAL Heater Voltage ............................................. Heater Surge Current ................................. Heater Current ............................................. Heater Warm-up Time ................................. Helix Voltage ............................................. Helix Current ............................................. Collector-1 Voltage .................................... Collector-1 Current .................................... Collector-2 Voltage .................................... Collector-2 Current .................................... RF Drive Power .......................................... Load VSWR ................................................ ENVIRONMENTAL Heat Sink Temperature Storage Temperature Min. 6.0 - - 180 7.8 - 3.0 - 1.5 - - - Max. 6.6 2.5 1.2 - 8.5 5.0 3.3 40 1.7 65 6 1.5 : 1 Unit V A A s kV mA kV mA kV mA dBm -
-30 -40
+90 +90
C C
2
DATA SHEET ET0454EJ1V0DS00
LD7714
TYPICAL OPERATION (Note 2, 3 and 5)
Unit GHz W V A kV mA kV mA mA kV mA dB dB dB/2.5 GHz dB/MHz deg./dB dBc dBc dB %
Frequency ................................................... Output Power ............................................. Heater Voltage (Note 4) ................................. Heater Current ............................................. Collector-1 Voltage Collector-1 Current Collector-2 Voltage Collector-2 Current .................................... .................................... .................................... ....................................
28.0 47 6.3 0.82 3.0 32.0 1.5 23.0 57.0 8.0 2.0 52 45 2.5 0.025 3.5 -31 -60 32.5 31
Cathode Current .......................................... Helix Voltage ............................................. Helix Current ............................................. Power Gain Gain Variation Gain Slope (SSG) .............................. (LSG) .............................. at 4 W .............................. at 4 W ..............................
AM-PM Conversion .................................... 3rd Order Intermodulation ........................... (two equal carriers, 4 W total) Spurious ................................................... Noise Figure ................................................ Overall Efficiency .......................................
Note 1 : Absolute rating should not be exceeded under continuous or transient conditions. A single absolute rating may be the limitation and simultaneous operation at more than one absolute rating may not be possible. Note 2 : The tube body is at ground potential in operation. Note 3 : All voltages are referred to the cathode potential except the heater voltage. Note 4 : The optimum operating parameters are shown on a test performance sheet for each tube. Note 5 : These characteristics and operating values may be changed as a result of additional information or product improvement. NEC should be consulted before using this information for equipment design. This data sheet should not be referred to a contractual specification.
DATA SHEET ET0454EJ1V0DS00
3
LD7714
LD7714 OUTLINE (Unit in mm)
38.30.5
190.5
6- 4.5 RF OUTPUT UG-599/U FLANGE WITH M3 THREADED HOLES
19.30.5
5.5 0.5 82 1 183 1 70 1
100 0.3
151 0.3
24.50.3 301
211 271 361
LEAD COLOR BROWN YELLOW RED GREEN BLACK
LEAD CONNECTIONS HEATER HEATER-CATHODE COLLECTOR-1 COLLECTOR-2 HELIX (GROUND)
LENGTH 500 mm MIN. 500 mm MIN. 500 mm MIN. 500 mm MIN. 500 mm MIN.
4
DATA SHEET ET0454EJ1V0DS00
265.5 2
260 2
RF INPUT TYPE K CONNECTOR FEMALE
LD7714
DATA SHEET ET0454EJ1V0DS00
5
LD7714
No part of this document may be copied or reproduced in any form or by any means without the prior written consent of NEC Corporation. NEC Corporation assumes no responsibility for any errors which may appear in this document. NEC Corporation does not assume any liability for infringement of patents, copyrights or other intellectual property rights of third parties by or arising from use of a device described herein or any other liability arising from use of such device. No license, either express, implied or otherwise, is granted under any patents, copyrights or other intellectual property rights of NEC Corporation or others. While NEC Corporation has been making continuous effort to enhance the reliability of its electronic components, the possibility of defects cannot be eliminated entirely. To minimize risks of damage or injury to persons or property arising from a defect in an NEC electronic component, customers must incorporate sufficient safety measures in its design, such as redundancy, fire-containment, and anti-failure features. NEC devices are classified into the following three quality grades: "Standard", "Special", and "Specific". The Specific quality grade applies only to devices developed based on a customer designated "quality assurance program" for a specific application. The recommended applications of a device depend on its quality grade, as indicated below. Customers must check the quality grade of each device before using it in a particular application. Standard: Computers, office equipment, communications equipment, test and measurement equipment, audio and visual equipment, home electronic appliances, machine tools, personal electronic equipment and industrial robots Special: Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster systems, anti-crime systems, safety equipment and medical equipment (not specifically designed for life support) Specific: Aircrafts, aerospace equipment, submersible repeaters, nuclear reactor control systems, life support systems or medical equipment for life support, etc. The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books. If customers intend to use NEC devices for applications other than those specified for Standard quality grade, they should contact an NEC sales representative in advance. Anti-radioactive design is not implemented in this product.


▲Up To Search▲   

 
Price & Availability of LD7714

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X